Airflow required for a sensible load
API · /hvacload-api
HVAC Air-Side Load API
HVAC air-side heat maths as an API, computed locally and deterministically with the classic standard-air factors — the sensible, latent and airflow numbers a mechanical engineer or HVAC technician sizes ducts and equipment with. The sensible endpoint gives the sensible heat an airflow carries to change temperature: Qs = 1.08 × CFM × ΔT (dry-bulb difference), where the 1.08 bundles standard-air density and specific heat — 2,000 CFM across a 20 °F difference is 43,200 BTU/hr, 3.6 tons — with the result in BTU/hr, tons and kW. The latent endpoint gives the latent (moisture) heat: Ql = 0.68 × CFM × ΔW, where ΔW is the humidity-ratio difference in grains of water per pound of dry air, the dehumidification part of a cooling load that runs high in humid climates and from people and cooking, and why air conditioners are sized on total, not just temperature. The airflow endpoint inverts the sensible relation: CFM = sensible load ÷ (1.08 × ΔT), the supply air needed at a chosen supply-to-room temperature difference (comfort cooling runs ~18–22 °F below room), the number that sets fan and duct size — sanity-checked against ~400 CFM per ton. Everything is computed locally and deterministically, so it is instant and private. Ideal for HVAC-design and load-calc tools, mechanical-estimating and commissioning utilities, and building-engineering apps. Pure local computation — no key, no third-party service, instant. Standard-air factors — adjust for altitude. 3 compute endpoints. For room rule-of-thumb sizing use an HVAC API; for moist-air properties a psychrometric API; for duct sizing a ductwork API.
API salute
salutare- Tempo di attività
- 100.00%
- Sondaggi del server · 24 ore su 24
- Latenza media
- 104 ms
- Sondaggi del server · 24 ore su 24
- Abbonati
- 4,206
- attiva
- Chiamate totali
- 0
- ultimi 7 giorni
Prezzi
Scegli un livello: fatturazione mensile, annullamento in qualsiasi momento.
Free
Gratis
- 5,700 chiamate/mese
- 2 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 5.700 Aufrufe/Monat
- 2 req/sec
- Sensible + latent + airflow
- Keine Kreditkarte
Starter
€11.70 /mese
- 57,500 chiamate/mese
- 6 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 57.500 Aufrufe/Monat
- 6 req/sec
- Tonnen, kW & Feuchtigkeitslasten
- E-Mail-Support
Pro
€37.00 /mese
- 240,000 chiamate/mese
- 15 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 240.000 Aufrufe/Monat
- 15 req/sec
- Lastberechnungs- und Design-Pipelines
- Prioritäts-Support
Mega
€113.80 /mese
- 1,195,000 chiamate/mese
- 40 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 1.195.000 Aufrufe/Monat
- 40 req/sec
- Firmen- und mechanischer Auftragnehmer-Maßstab
- Dedizierte SLA
Costruito da
Correlato APIs
Altro APIs con tag sovrapposti.
Electric Motor FLA API
Electric-motor electrical maths as an API, computed locally and deterministically — the full-load-current, NEC-sizing and starting-current numbers an electrician, panel designer or estimator runs for every motor circuit. The full-load-amps endpoint gives the motor current from its power, voltage and phase: FLA = (output ÷ efficiency) ÷ (√3 × volts × power factor) for three-phase (drop the √3 for single-phase) — a 10 hp, 460 V, three-phase motor at 90 % efficiency and 0.85 power factor draws about 12.2 A — and it also returns the input kW and kVA. The sizing endpoint applies NEC Article 430 from the full-load current: branch-circuit conductors at 125 %, overload protection at 115–125 % by service factor, and branch-circuit short-circuit/ground-fault protection up to 250 % for an inverse-time breaker or 175 % for a time-delay fuse — the larger protection lets the inrush pass while the overload guards the windings. The starting endpoint gives the locked-rotor (inrush) current, about six times full-load for an across-the-line start, the figure that sets the voltage dip and why soft starters and VFDs exist. Everything is computed locally and deterministically, so it is instant and private. Ideal for electrical-design and estimating tools, panel-builder and field utilities, and engineering calculators. Pure local computation — no key, no third-party service, instant. Calculated values — use the NEC FLC tables for code work. 3 compute endpoints. For general three-phase power use a three-phase API; for conduit fill a conduit API.
api.oanor.com/motorfla-api
Heat Pump COP API
Heat-pump and refrigeration performance maths as an API, computed locally and deterministically — the efficiency numbers an HVAC engineer, energy auditor or heat-pump installer actually works with. The cop endpoint gives the coefficient of performance and the US EER rating from the thermal capacity and the electrical power: a unit moving 7 kW of heat on 2 kW of electricity has a COP of 3.5 (an EER of 12), meaning 3.5 units of heating or cooling for every unit of electricity — which is why a heat pump beats resistance heating, where the COP is exactly 1. The carnot endpoint gives the unbeatable ideal limit set only by the absolute temperatures — heating = Th ÷ (Th − Tc), cooling = Tc ÷ (Th − Tc) in kelvin, where heating COP always equals cooling COP plus one — and, given a real COP, the second-law efficiency that says how close the machine runs to that ceiling; the smaller the temperature lift, the higher the limit, which is why ground-source and low-temperature systems beat air-source on a cold day. The capacity endpoint turns electrical power and a COP into the delivered heating or cooling in kilowatts, BTU per hour and tons of refrigeration — the extra energy over the electricity is pulled from the outside air, ground or water. Everything is computed locally and deterministically, so it is instant and private. Ideal for HVAC and refrigeration engineers, energy auditors, heat-pump and building-performance tools, and sustainability dashboards. Pure local computation — no key, no third-party service, instant. Estimates at the stated conditions — real COP falls as the temperature lift rises. 3 compute endpoints. For room sizing use an HVAC BTU API; for moist-air properties use a psychrometric API.
api.oanor.com/heatpump-api
Steam Boiler API
Steam-boiler engineering maths as an API, computed locally and deterministically — the three numbers a boiler operator, plant engineer or steam-system designer actually works with. The boiler-hp endpoint converts a required heat output into boiler horsepower (heat ÷ 33,475 BTU/hr, the standard definition), the equivalent steam output in pounds per hour "from and at" 212 °F (34.5 lb/hr per BHP) and the output in kilowatts — a 1,000,000 BTU/hr load is about 29.9 BHP or 1,031 lb/hr of steam. The factor-of-evaporation endpoint gives the real capacity for your feedwater: the factor = (the total heat of the steam − the feedwater heat) ÷ 970.3, always greater than one because the boiler must add the sensible heat to bring water up to boiling, so a boiler rated "from and at" 212 °F actually makes less with 60 °F feedwater — which is exactly why preheating feedwater with an economiser raises capacity and saves fuel. The blowdown endpoint gives the continuous blowdown rate to hold the boiler water within its dissolved-solids limit: blowdown = steam × feedwater TDS ÷ (boiler limit − feedwater TDS), with the cycles of concentration and the blowdown as a percentage of feedwater — better feedwater means more cycles, less blowdown and less wasted hot water. Everything is computed locally and deterministically, so it is instant and private. Ideal for boiler operators, steam-plant and HVAC engineers, energy auditors, water-treatment specialists and process-engineering tools. Pure local computation — no key, no third-party service, instant. Engineering estimates — verify against the manufacturer data and local code. 3 compute endpoints. For moist-air properties use a psychrometric API; for compressed air use a compressor API.
api.oanor.com/boiler-api
Pipe Insulation API
Pipe-insulation heat-loss maths as an API, computed locally and deterministically — the radial heat loss, thickness and energy-cost numbers a mechanical engineer or energy auditor sizes lagging with. The heat-loss endpoint gives the loss per linear foot through cylindrical insulation, Q/L = 2π·(k/12)·ΔT ÷ ln(r2/r1), where k is the insulation conductivity (BTU·in/hr·ft²·°F, ~0.25 for fibreglass), r1 the pipe radius and r2 the outer radius — a 2-inch line at 300 °F with one inch of fibreglass loses about 43 BTU/hr per foot, and because the relationship is logarithmic, doubling the thickness does not halve the loss. The thickness endpoint inverts it for a target loss: ln(r2/r1) = 2π·(k/12)·ΔT ÷ target, then thickness = r2 − r1, showing the economic-thickness point beyond which more material rarely pays. The annual-cost endpoint turns loss per foot into the yearly heat lost and fuel cost over a run of pipe, the number that justifies the lagging. Everything is computed locally and deterministically, so it is instant and private. Ideal for mechanical-design and energy-audit apps, insulation-contractor and process-piping tools, building-services calculators, and engineering aids. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 compute endpoints. Ignores the outer air film (real loss slightly lower). For flat walls and roofs use a U-value API.
api.oanor.com/pipeinsulation-api
Domande frequenti
Risposte rapide su prezzi, quote e integrazione.
Come ottengo una chiave API per HVAC Air-Side Load API?
Qual è il limite di velocità di HVAC Air-Side Load API?
Quanto costa HVAC Air-Side Load API?
Posso cancellare l'abbonamento in qualsiasi momento?
HVAC Air-Side Load API è conforme al GDPR?
Scegli un endpoint dall'elenco a sinistra per visualizzarne i dettagli e provarlo.
Frammenti di codice
Iscriviti per ottenere una chiave API, quindi chiama qualsiasi percorso sotto il tuo slug.
curl https://api.oanor.com/hvacload-api/SOME_PATH \
-H "x-oanor-key: oanor_test_..."
const res = await fetch("https://api.oanor.com/hvacload-api/SOME_PATH", {
headers: { "x-oanor-key": "oanor_test_..." }
});
const data = await res.json();
$ch = curl_init("https://api.oanor.com/hvacload-api/SOME_PATH");
curl_setopt($ch, CURLOPT_RETURNTRANSFER, true);
curl_setopt($ch, CURLOPT_HTTPHEADER, ["x-oanor-key: oanor_test_..."]);
$response = curl_exec($ch);
import requests
r = requests.get(
"https://api.oanor.com/hvacload-api/SOME_PATH",
headers={"x-oanor-key": "oanor_test_..."},
)
print(r.json())
Valutazioni
Accedi per votare.
Nessuna recensione ancora.
Discussione
Fai domande, condividi consigli, ricevi risposte dal provider e dagli altri sviluppatori. Pubblico — chiunque può leggere.
Accedi per scrivere o rispondere.
AccediNuova discussione
·
-
Risposta del provider
🔒 Discussione bloccata — non si può più rispondere.
-
·
- Nessuna discussione — inizia tu.
Supporto
Supporto privato 1:1 con il provider — fatturazione, integrazione, account. Solo tu e il team del provider vedete questi thread.
Accedi per aprire un ticket di supporto.
AccediApri nuovo ticket
Descrivi cosa ti serve. Il team del provider riceve un'email e risponde sulla pagina del ticket.
-
·
Urgente - Nessun ticket per questa API.