Full-load current from power
API · /motorfla-api
Electric Motor FLA API
Electric-motor electrical maths as an API, computed locally and deterministically — the full-load-current, NEC-sizing and starting-current numbers an electrician, panel designer or estimator runs for every motor circuit. The full-load-amps endpoint gives the motor current from its power, voltage and phase: FLA = (output ÷ efficiency) ÷ (√3 × volts × power factor) for three-phase (drop the √3 for single-phase) — a 10 hp, 460 V, three-phase motor at 90 % efficiency and 0.85 power factor draws about 12.2 A — and it also returns the input kW and kVA. The sizing endpoint applies NEC Article 430 from the full-load current: branch-circuit conductors at 125 %, overload protection at 115–125 % by service factor, and branch-circuit short-circuit/ground-fault protection up to 250 % for an inverse-time breaker or 175 % for a time-delay fuse — the larger protection lets the inrush pass while the overload guards the windings. The starting endpoint gives the locked-rotor (inrush) current, about six times full-load for an across-the-line start, the figure that sets the voltage dip and why soft starters and VFDs exist. Everything is computed locally and deterministically, so it is instant and private. Ideal for electrical-design and estimating tools, panel-builder and field utilities, and engineering calculators. Pure local computation — no key, no third-party service, instant. Calculated values — use the NEC FLC tables for code work. 3 compute endpoints. For general three-phase power use a three-phase API; for conduit fill a conduit API.
API salute
salutare- Tempo di attività
- 100.00%
- Sondaggi del server · 24 ore su 24
- Latenza media
- 80 ms
- Sondaggi del server · 24 ore su 24
- Abbonati
- 4,688
- attiva
- Chiamate totali
- 0
- ultimi 7 giorni
Prezzi
Scegli un livello: fatturazione mensile, annullamento in qualsiasi momento.
Free
Gratis
- 5,800 chiamate/mese
- 2 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 5.800 Aufrufe/Monat
- 2 req/sec
- FLA + NEC-Bemessung + Start
- Keine Kreditkarte
Starter
€11.60 /mese
- 58,000 chiamate/mese
- 6 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 58.000 Aufrufe/Monat
- 6 req/sec
- 1φ/3φ, Wirkungsgrad & Leistungsfaktor
- E-Mail-Support
Pro
€37.20 /mese
- 243,000 chiamate/mese
- 15 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 243.000 Aufrufe/Monat
- 15 req/sec
- Panel-Design & Schätzungspipelines
- Priority-Support
Mega
€114.50 /mese
- 1,210,000 chiamate/mese
- 40 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 1.210.000 Aufrufe/Monat
- 40 req/sec
- Contractor & OEM-Skalierung
- Dedizierte SLA
Costruito da
Correlato APIs
Altro APIs con tag sovrapposti.
Sauna Heater API
Sauna-Heizer-Berechnungen als API, lokal und deterministisch berechnet – die Heizleistung, Steinmasse und elektrischen Werte, die ein Saunabauer, Installateur oder Wellnesshändler für eine Kabine dimensioniert. Der Heizgrößen-Endpoint gibt die Leistung: etwa 1 kW pro 1,3 m³ gut isolierter Kabine (Raumvolumen ÷ 1,3), wobei kalte Oberflächen, die der Heizer ebenfalls erwärmen muss – eine Glastür oder -wand, nackter Stein, Fliesen oder ungedämmtes Holz – etwa 1,2 m³ äquivalentes Volumen pro Quadratmeter hinzufügen, sodass ein 10 m³ Raum mit einer 2 m² Glastür etwa einen 10 kW Heizer benötigt, aufgerundet auf die nächste Standardgröße. Der Steine-Endpoint gibt die empfohlene Saunasteinmasse, etwa 10–20 kg pro kW (mehr Steine für einen weicheren, dampfigen Löyly, weniger für eine schnellere Aufheizzeit), mit einem Hinweis, richtige Peridotit/Olivin-Steine locker gestapelt zu verwenden. Der Elektrik-Endpoint gibt den Strom an, den der Widerstandsheizer zieht – Leistung ÷ Spannung für einphasig oder ÷ (√3 × Spannung) für dreiphasig, da die meisten Heizer über ~4 kW dreiphasig angeschlossen werden, um den Strom pro Leitung und Kabelquerschnitt gering zu halten – zur Dimensionierung des Schutzschalters und des dedizierten FI-geschützten Stromkreises. Alles wird lokal und deterministisch berechnet, daher ist es sofort und privat. Ideal für Sauna- und Wellnesshändler, Heimwerker- und DIY-Tools sowie HLK-/Elektro-Schätzungs-Apps. Reine lokale Berechnung – kein Key, kein Drittanbieter-Service, sofort. Schätzungen – folgen Sie der Tabelle des Heizerherstellers und den örtlichen Elektrovorschriften. 3 Compute-Endpoints. Für Dampfkesselberechnungen verwenden Sie eine Boiler-API; für Raumwärmeverlust eine U-Wert-API.
api.oanor.com/saunaheater-api
Cable Tray Fill API
Cable-tray fill engineering maths as an API, computed locally and deterministically from NEC Article 392 — the allowable-fill, single-layer and tray-width numbers an electrician, estimator or designer runs for a tray run. The fill endpoint applies NEC 392.22(A)(1) Column 1 for multiconductor power and lighting cables no larger than 4/0 in a ladder or ventilated-bottom tray: the total cable cross-sectional area is capped at the tray width × 7/6, so a 12-inch tray allows 14 in² — sum every cable's csa, get the percentage fill and whether it is within code, with the spare area left. The large-cable endpoint covers cables 4/0 and larger, which must lie in a single layer with the sum of their diameters not exceeding the tray width — no stacking — so it returns the spare width and the code check. The min-width endpoint inverts the rule to size the tray: minimum width = cable area × 6/7, rounded up to a standard 6/9/12/18/24/30/36-inch width, leaving room for spare capacity and future cables. Everything is computed locally and deterministically, so it is instant and private. Ideal for electrical-design and estimating tools, industrial and OSP utilities, and code-check calculators. Pure local computation — no key, no third-party service, instant. Ladder/ventilated trays; solid-bottom and mixed fills use the other NEC columns, and ampacity must be derated for fill. 3 compute endpoints. For conduit and box fill use a conduit API.
api.oanor.com/cabletray-api
Conduit Fill API
NEC conduit-fill and box-fill maths as an API, computed locally and deterministically — the electrical-code calculations an electrician or estimator does on every run. The conduit-fill endpoint takes a set of conductors (as size:count pairs, e.g. 12:3,10:2) and a conduit trade size and returns the conductor cross-sectional area, the conduit's internal area, the fill percentage and whether it stays within the NEC Chapter 9 limit — 53 % for a single conductor, 31 % for two, 40 % for three or more — so nine #12 THHN fill a half-inch EMT to 39 % (legal) but ten do not. The box-fill endpoint applies NEC 314.16(B): each conductor adds its free-space allowance (2.00 in³ for #14, 2.25 for #12, and so on), a device yoke counts as two, internal cable clamps as one, and all equipment grounds together as one — all at the largest conductor's volume — to give the minimum junction-box size, checked against a box volume if you give one. Uses the THHN/THWN and EMT areas from NEC Chapter 9. Everything is computed locally and deterministically, so it is instant and private. Ideal for electrical-contractor, estimating, inspection and electrician app developers, conduit and box-sizing tools, and apprentice training. Pure local computation — no key, no third-party service, instant. Imperial: square inches and cubic inches. Live, nothing stored. 2 compute endpoints. Always verify against the adopted code edition — this is an estimating aid, not an inspection.
api.oanor.com/conduit-api
Three-Phase Power API
Three-phase AC power maths as an API, computed locally and deterministically. The power endpoint solves the three-phase power triangle from the line-to-line voltage, the line current and the power factor — the apparent power S = √3·V_L·I_L in volt-amperes, the real power P = S·cosφ in watts, the reactive power Q = S·sinφ in VAR and the phase angle — or works backwards to find the line current a load draws for a given real power. The wye endpoint gives the star-connection relationships, where the line-to-line voltage is √3 times the phase voltage and the line and phase currents are equal. The delta endpoint gives the delta-connection relationships, where the line and phase voltages are equal and the line current is √3 times the phase current. Supply a line or phase quantity and it returns the rest. Everything is computed locally and deterministically, so it is instant and private. Ideal for electrical, motor, industrial-automation, solar-inverter and building-services app developers, switchboard and motor-sizing tools, and electrical-engineering education. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 endpoints. This is balanced three-phase power; for the single-phase power triangle use a power-factor API and for voltage drop a voltage-drop API.
api.oanor.com/threephase-api
Domande frequenti
Risposte rapide su prezzi, quote e integrazione.
Come ottengo una chiave API per Electric Motor FLA API?
Qual è il limite di velocità di Electric Motor FLA API?
Quanto costa Electric Motor FLA API?
Posso cancellare l'abbonamento in qualsiasi momento?
Electric Motor FLA API è conforme al GDPR?
Scegli un endpoint dall'elenco a sinistra per visualizzarne i dettagli e provarlo.
Frammenti di codice
Iscriviti per ottenere una chiave API, quindi chiama qualsiasi percorso sotto il tuo slug.
curl https://api.oanor.com/motorfla-api/SOME_PATH \
-H "x-oanor-key: oanor_test_..."
const res = await fetch("https://api.oanor.com/motorfla-api/SOME_PATH", {
headers: { "x-oanor-key": "oanor_test_..." }
});
const data = await res.json();
$ch = curl_init("https://api.oanor.com/motorfla-api/SOME_PATH");
curl_setopt($ch, CURLOPT_RETURNTRANSFER, true);
curl_setopt($ch, CURLOPT_HTTPHEADER, ["x-oanor-key: oanor_test_..."]);
$response = curl_exec($ch);
import requests
r = requests.get(
"https://api.oanor.com/motorfla-api/SOME_PATH",
headers={"x-oanor-key": "oanor_test_..."},
)
print(r.json())
Valutazioni
Accedi per votare.
Nessuna recensione ancora.
Discussione
Fai domande, condividi consigli, ricevi risposte dal provider e dagli altri sviluppatori. Pubblico — chiunque può leggere.
Accedi per scrivere o rispondere.
AccediNuova discussione
·
-
Risposta del provider
🔒 Discussione bloccata — non si può più rispondere.
-
·
- Nessuna discussione — inizia tu.
Supporto
Supporto privato 1:1 con il provider — fatturazione, integrazione, account. Solo tu e il team del provider vedete questi thread.
Accedi per aprire un ticket di supporto.
AccediApri nuovo ticket
Descrivi cosa ti serve. Il team del provider riceve un'email e risponde sulla pagina del ticket.
-
·
Urgente - Nessun ticket per questa API.