Delivered capacity from power and COP
API · /heatpump-api
Heat Pump COP API
Heat-pump and refrigeration performance maths as an API, computed locally and deterministically — the efficiency numbers an HVAC engineer, energy auditor or heat-pump installer actually works with. The cop endpoint gives the coefficient of performance and the US EER rating from the thermal capacity and the electrical power: a unit moving 7 kW of heat on 2 kW of electricity has a COP of 3.5 (an EER of 12), meaning 3.5 units of heating or cooling for every unit of electricity — which is why a heat pump beats resistance heating, where the COP is exactly 1. The carnot endpoint gives the unbeatable ideal limit set only by the absolute temperatures — heating = Th ÷ (Th − Tc), cooling = Tc ÷ (Th − Tc) in kelvin, where heating COP always equals cooling COP plus one — and, given a real COP, the second-law efficiency that says how close the machine runs to that ceiling; the smaller the temperature lift, the higher the limit, which is why ground-source and low-temperature systems beat air-source on a cold day. The capacity endpoint turns electrical power and a COP into the delivered heating or cooling in kilowatts, BTU per hour and tons of refrigeration — the extra energy over the electricity is pulled from the outside air, ground or water. Everything is computed locally and deterministically, so it is instant and private. Ideal for HVAC and refrigeration engineers, energy auditors, heat-pump and building-performance tools, and sustainability dashboards. Pure local computation — no key, no third-party service, instant. Estimates at the stated conditions — real COP falls as the temperature lift rises. 3 compute endpoints. For room sizing use an HVAC BTU API; for moist-air properties use a psychrometric API.
API salute
salutare- Tempo di attività
- 100.00%
- Sondaggi del server · 24 ore su 24
- Latenza media
- 86 ms
- Sondaggi del server · 24 ore su 24
- Abbonati
- 3,895
- attiva
- Chiamate totali
- 4
- ultimi 7 giorni
Prezzi
Scegli un livello: fatturazione mensile, annullamento in qualsiasi momento.
Free
Gratis
- 5,900 chiamate/mese
- 2 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 5.900 Aufrufe/Monat
- 2 req/sec
- COP + Carnot + Kapazität
- Keine Kreditkarte
Starter
€11.80 /mese
- 66,000 chiamate/mese
- 6 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 66.000 Aufrufe/Monat
- 6 req/sec
- EER, Second-Law-Effizienz, Tonnen
- E-Mail-Support
Pro
€36.50 /mese
- 272,000 chiamate/mese
- 15 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 272.000 Aufrufe/Monat
- 15 req/sec
- Energieaudit- und Gebäudeleistungs-Pipelines
- Prioritäts-Support
Mega
€112.00 /mese
- 1,340,000 chiamate/mese
- 40 richieste/secondo
- Tetto rigido (429 sopra la quota, nessuna eccedenza)
- 1.340.000 Aufrufe/Monat
- 40 req/sec
- Flotten- & Portfolio-Skalierung
- Dedizierte SLA
Costruito da
Correlato APIs
Altro APIs con tag sovrapposti.
Pool Heating API
Swimming-pool and spa heating maths as an API, computed locally and deterministically — the thermodynamics a pool owner, builder or service tech sizes a heater and budgets a heat-up with. The heat-time endpoint gives the hours to warm a body of water: energy = gallons × 8.34 lb/gal × the temperature rise in °F (that many BTU), divided by the heater's BTU/hr output — raising 20,000 gallons by 10 °F is 1,668,000 BTU, about 4.2 hours on a 400,000 BTU/hr gas heater before surface losses. The heater-size endpoint inverts it: the output you need to hit a temperature rise within a target time, so the same job in 24 hours wants only about 69,500 BTU/hr. The heat-pump endpoint gives a heat pump's electricity and cost — kWh = thermal BTU ÷ 3412 ÷ the COP (5–6 for pool units in mild weather) — so that 1,668,000 BTU costs about 89 kWh at a COP of 5.5, a fraction of resistance heat. Pass the temperature rise directly, or a current and target temperature. Everything is computed locally and deterministically, so it is instant and private. Ideal for pool-builder and service apps, heater-sizing and quote tools, spa and hot-tub calculators, and energy-comparison sites. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 compute endpoints. Ideal figures — add for surface and wind losses. For pool chemistry use a pool-chemistry API.
api.oanor.com/poolheat-api
Carnot Heat Engine API
Heat-engine efficiency and coefficient of performance as an API, computed locally and deterministically. The efficiency endpoint gives the Carnot maximum efficiency of any heat engine working between two temperatures, η = 1 − Tc/Th (in kelvin) — the absolute upper limit no real engine can beat — and, given a heat input, the maximum work it could produce and the heat it must reject. The heat-pump endpoint gives the Carnot coefficient of performance of a heat pump, COP = Th/(Th − Tc), and of a refrigerator or air conditioner, COP = Tc/(Th − Tc), and the heat moved for a given work input. The engine endpoint analyses a real engine from its heat balance: from any two of the heat input, the work output, the efficiency or the heat rejected it returns the rest using η = W/Qh and Qc = Qh − W, and — given the reservoir temperatures — compares it to the Carnot limit and reports the second-law (exergy) efficiency. Temperatures accept kelvin, Celsius or Fahrenheit. Everything is computed locally and deterministically, so it is instant and private. Ideal for thermodynamics-education tools, engine, turbine and HVAC design, refrigeration and heat-pump apps, and energy-systems software. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 endpoints. This is heat-engine and refrigeration-cycle efficiency; for sensible heat use a specific-heat API and for heat-exchanger LMTD use a heat-exchanger API.
api.oanor.com/carnot-api
HVAC Air-Side Load API
HVAC air-side heat maths as an API, computed locally and deterministically with the classic standard-air factors — the sensible, latent and airflow numbers a mechanical engineer or HVAC technician sizes ducts and equipment with. The sensible endpoint gives the sensible heat an airflow carries to change temperature: Qs = 1.08 × CFM × ΔT (dry-bulb difference), where the 1.08 bundles standard-air density and specific heat — 2,000 CFM across a 20 °F difference is 43,200 BTU/hr, 3.6 tons — with the result in BTU/hr, tons and kW. The latent endpoint gives the latent (moisture) heat: Ql = 0.68 × CFM × ΔW, where ΔW is the humidity-ratio difference in grains of water per pound of dry air, the dehumidification part of a cooling load that runs high in humid climates and from people and cooking, and why air conditioners are sized on total, not just temperature. The airflow endpoint inverts the sensible relation: CFM = sensible load ÷ (1.08 × ΔT), the supply air needed at a chosen supply-to-room temperature difference (comfort cooling runs ~18–22 °F below room), the number that sets fan and duct size — sanity-checked against ~400 CFM per ton. Everything is computed locally and deterministically, so it is instant and private. Ideal for HVAC-design and load-calc tools, mechanical-estimating and commissioning utilities, and building-engineering apps. Pure local computation — no key, no third-party service, instant. Standard-air factors — adjust for altitude. 3 compute endpoints. For room rule-of-thumb sizing use an HVAC API; for moist-air properties a psychrometric API; for duct sizing a ductwork API.
api.oanor.com/hvacload-api
Electric Motor FLA API
Electric-motor electrical maths as an API, computed locally and deterministically — the full-load-current, NEC-sizing and starting-current numbers an electrician, panel designer or estimator runs for every motor circuit. The full-load-amps endpoint gives the motor current from its power, voltage and phase: FLA = (output ÷ efficiency) ÷ (√3 × volts × power factor) for three-phase (drop the √3 for single-phase) — a 10 hp, 460 V, three-phase motor at 90 % efficiency and 0.85 power factor draws about 12.2 A — and it also returns the input kW and kVA. The sizing endpoint applies NEC Article 430 from the full-load current: branch-circuit conductors at 125 %, overload protection at 115–125 % by service factor, and branch-circuit short-circuit/ground-fault protection up to 250 % for an inverse-time breaker or 175 % for a time-delay fuse — the larger protection lets the inrush pass while the overload guards the windings. The starting endpoint gives the locked-rotor (inrush) current, about six times full-load for an across-the-line start, the figure that sets the voltage dip and why soft starters and VFDs exist. Everything is computed locally and deterministically, so it is instant and private. Ideal for electrical-design and estimating tools, panel-builder and field utilities, and engineering calculators. Pure local computation — no key, no third-party service, instant. Calculated values — use the NEC FLC tables for code work. 3 compute endpoints. For general three-phase power use a three-phase API; for conduit fill a conduit API.
api.oanor.com/motorfla-api
Domande frequenti
Risposte rapide su prezzi, quote e integrazione.
Come ottengo una chiave API per Heat Pump COP API?
Qual è il limite di velocità di Heat Pump COP API?
Quanto costa Heat Pump COP API?
Posso cancellare l'abbonamento in qualsiasi momento?
Heat Pump COP API è conforme al GDPR?
Scegli un endpoint dall'elenco a sinistra per visualizzarne i dettagli e provarlo.
Frammenti di codice
Iscriviti per ottenere una chiave API, quindi chiama qualsiasi percorso sotto il tuo slug.
curl https://api.oanor.com/heatpump-api/SOME_PATH \
-H "x-oanor-key: oanor_test_..."
const res = await fetch("https://api.oanor.com/heatpump-api/SOME_PATH", {
headers: { "x-oanor-key": "oanor_test_..." }
});
const data = await res.json();
$ch = curl_init("https://api.oanor.com/heatpump-api/SOME_PATH");
curl_setopt($ch, CURLOPT_RETURNTRANSFER, true);
curl_setopt($ch, CURLOPT_HTTPHEADER, ["x-oanor-key: oanor_test_..."]);
$response = curl_exec($ch);
import requests
r = requests.get(
"https://api.oanor.com/heatpump-api/SOME_PATH",
headers={"x-oanor-key": "oanor_test_..."},
)
print(r.json())
Valutazioni
Accedi per votare.
Nessuna recensione ancora.
Discussione
Fai domande, condividi consigli, ricevi risposte dal provider e dagli altri sviluppatori. Pubblico — chiunque può leggere.
Accedi per scrivere o rispondere.
AccediNuova discussione
·
-
Risposta del provider
🔒 Discussione bloccata — non si può più rispondere.
-
·
- Nessuna discussione — inizia tu.
Supporto
Supporto privato 1:1 con il provider — fatturazione, integrazione, account. Solo tu e il team del provider vedete questi thread.
Accedi per aprire un ticket di supporto.
AccediApri nuovo ticket
Descrivi cosa ti serve. Il team del provider riceve un'email e risponde sulla pagina del ticket.
-
·
Urgente - Nessun ticket per questa API.