/v1/factor-of-evaporation
Factor of evaporation and real capacity
Probeer het live
10 gratis calls per dag — geen registratie, geen API-key. Loopt via de oanor-gateway.
Het werkt. Haal een API-key op en gebruik hem in je project.
Verkrijg een API-sleutelCodefragmenten
curl "https://api.oanor.com/boiler-api/v1/factor-of-evaporation" \ -H "x-oanor-key: oanor_test_..."
await fetch("https://api.oanor.com/boiler-api/v1/factor-of-evaporation", {
headers: { "x-oanor-key": "oanor_test_..." }
});
$ch = curl_init("https://api.oanor.com/boiler-api/v1/factor-of-evaporation");
curl_setopt($ch, CURLOPT_HTTPHEADER, ["x-oanor-key: oanor_test_..."]);
curl_setopt($ch, CURLOPT_RETURNTRANSFER, true);
$out = curl_exec($ch);
import requests
requests.get(
"https://api.oanor.com/boiler-api/v1/factor-of-evaporation",
headers={"x-oanor-key": "oanor_test_..."}
)
Voorbeeldrespons
Een echte respons van dit endpoint, vastgelegd bij de laatste health check.
{
"data": {
"note": "The factor of evaporation = (total heat of the steam − the feedwater heat) ÷ 970.3. It is always ≥ 1 because real feedwater is below 212 °F, so the boiler must add the sensible heat too. Divide a 'from and at 212 °F' rating by this factor to get the real output at your feedwater temperature — which is why preheating feedwater (e.g. with an economiser) raises capacity and saves fuel.",
"inputs": {
"feedwater_temp_f": 60,
"from_and_at_lb_hr": 1000,
"steam_total_heat_btu_lb": 1150.4
},
"actual_output_lb_hr": 864.5,
"factor_of_evaporation": 1.1568
},
"meta": {
"timestamp": "2026-06-06T23:53:55.985Z",
"request_id": "c8faedc3-813c-4ad6-a3af-97d58c8bf992"
},
"status": "ok",
"message": "Factor of evaporation",
"success": true
}