API · /voltagedivider-api

Voltage Divider API

healthy 4,087 Subscribers

Resistive voltage-divider circuit design as an API, computed locally and deterministically. The divide endpoint takes an input voltage and two resistors and returns the output voltage Vout = Vin·R2/(R1+R2), the current I = Vin/(R1+R2) that flows through the chain, and the power dissipated in each resistor and in total — a 12 V source with R1 = 1 kΩ and R2 = 2 kΩ gives 8 V at 4 mA. The loaded endpoint adds a load resistor across R2, computes the parallel combination R2′ = R2·RL/(R2+RL) and the loaded output Vout = Vin·R2′/(R1+R2′), and reports the droop in volts and percent against the unloaded value, the classic mistake when a divider feeds a real load. The resistor endpoint sizes the missing resistor for a target output — R2 = R1·Vout/(Vin−Vout) or R1 = R2·(Vin−Vout)/Vout — so you can pick parts for a reference or sensor-bias point. All quantities are volts, ohms, amps and watts. Everything is computed locally and deterministically, so it is instant and private. Ideal for electronics, embedded, hardware, sensor-interfacing and EE-education app developers, reference-voltage and bias-network tools, and maker software. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 endpoints. This is the resistive divider; for a single Ohm’s-law relationship use an Ohm’s-law API and for RC/RL filters an RC-filter API.

api.oanor.com/voltagedivider-api
Get an API key Try in playground → Contact provider

Machine-readable spec so AI agents can integrate this API.

/api/voltagedivider-api/openapi.json
/api/voltagedivider-api/llms.txt

Discovery: GET /api/index.json lists every API.

API health

healthy
Uptime
100.00%
Server probes · 24h
Avg latency
92 ms
Server probes · 24h
Subscribers
4,087
active
Total calls
4
last 7 days
status Full status page → · 8 probes/24h

Pricing

Pick a tier — billed monthly, cancel anytime.

Free

Free

  • 5,200 calls / month
  • 2 requests / second
  • Hard cap (429 above quota, no overage)
  • 5,200 calls/month
  • 2 req/sec
  • Divide + loaded + resistor solver
  • No credit card
Sign in to subscribe

Starter

€5.20 /month

  • 52,000 calls / month
  • 6 requests / second
  • Hard cap (429 above quota, no overage)
  • 52,000 calls/month
  • 6 req/sec
  • Loaded divider droop, part sizing
  • Email support
Sign in to subscribe

Pro

€14.80 /month

  • 240,000 calls / month
  • 15 requests / second
  • Hard cap (429 above quota, no overage)
  • 240,000 calls/month
  • 15 req/sec
  • Embedded & sensor-bias pipelines
  • Priority support
Sign in to subscribe

Mega

€46.50 /month

  • 1,380,000 calls / month
  • 40 requests / second
  • Hard cap (429 above quota, no overage)
  • 1,380,000 calls/month
  • 40 req/sec
  • Platform scale
  • Dedicated SLA
Sign in to subscribe

Built by

Related APIs

Other APIs with overlapping tags.

RC Filter API

First-order RC and RL passive-filter design as an API, computed locally and deterministically. The lowpass and highpass endpoints take a resistor and capacitor (RC) or a resistor and inductor (RL) and return the −3 dB cutoff frequency (fc = 1/(2πRC) for RC, R/(2πL) for RL), the time constant (τ = RC or L/R) and the angular cutoff; pass a frequency as well and they add the magnitude response as a linear gain and in decibels and the phase shift in degrees — a 1 kΩ / 1 µF low-pass has fc ≈ 159.15 Hz, and right at the cutoff the gain is −3.01 dB with −45° phase for a low-pass or +45° for a high-pass. The component endpoint solves the missing one of fc, R and C from the other two (fc = 1/(2πRC)), so you can size a resistor or capacitor for a target cutoff. All quantities are SI: ohms, farads, henries and hertz. Everything is computed locally and deterministically, so it is instant and private. Ideal for electronics, audio, embedded, signal-processing and EE-education app developers, filter-design and circuit-sizing tools, and maker software. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 endpoints. This is first-order single-pole filter design; for full RLC impedance and resonance use an impedance API and for stored capacitor energy a capacitor API.

api.oanor.com/rcfilter-api

Chebyshev Filter API

Chebyshev Type I filter-design maths as an API, computed locally and deterministically. The order endpoint computes the minimum filter order to meet a specification, n = ⌈acosh(√((10^(As/10)−1)/(10^(Ap/10)−1))) / acosh(fs/fp)⌉, from the passband edge frequency and its ripple and the stopband edge and its required attenuation — a Chebyshev filter usually needs a lower order than a Butterworth for the same specification, trading a flat passband for equiripple. The response endpoint computes the equiripple magnitude response, |H| = 1/√(1 + ε²·Tₙ²(f/fc)) with the ripple factor ε = √(10^(Ap/10) − 1) and the Chebyshev polynomial Tₙ, in linear and decibel form — in the passband the magnitude ripples between 0 and −Ap dB and reaches exactly −Ap dB at the cutoff, then rolls off faster than a Butterworth. The ripple endpoint converts between the passband ripple in decibels and the ripple factor ε, with the passband maximum and minimum. Frequencies are in hertz, ripple and attenuation in decibels and the order a positive integer. Everything is computed locally and deterministically, so it is instant and private. Ideal for DSP, audio, RF, communications and instrumentation app developers, filter-design and selectivity tools, and signal-processing education. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 endpoints. This is the Chebyshev Type I filter; for the maximally-flat Butterworth use a Butterworth API.

api.oanor.com/chebyshev-api

Butterworth Filter API

Butterworth-filter design maths as an API, computed locally and deterministically. The order endpoint computes the minimum filter order needed to meet a specification — from the passband edge frequency and its allowed ripple and the stopband edge frequency and its required attenuation it returns the exact and rounded-up order, n = ⌈log10((10^(As/10)−1)/(10^(Ap/10)−1)) / (2·log10(fs/fp))⌉, where each extra order adds 20 dB per decade of roll-off. The response endpoint computes the maximally-flat magnitude response of an n-th order Butterworth filter at a frequency, |H| = 1/√(1 + (f/fc)^(2n)), in linear and decibel form with the attenuation and the asymptotic roll-off — the response is exactly −3.01 dB at the cutoff for any order. The poles endpoint gives the s-plane pole locations, equally spaced on a circle of radius ωc in the left half-plane at angles π·(2k+n−1)/(2n), all stable. Frequencies are in hertz (or any consistent unit), ripple and attenuation in decibels and the order a positive integer. Everything is computed locally and deterministically, so it is instant and private. Ideal for DSP, audio, RF, instrumentation and embedded app developers, anti-aliasing and filter-design tools, and signal-processing education. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 endpoints. This is the Butterworth filter; for a single-pole RC cutoff and resonance use a resonance API and for AC impedance an impedance API.

api.oanor.com/butterworth-api

Zener Regulator API

Zener-diode voltage-regulator electronics maths as an API, computed locally and deterministically. The series-resistor endpoint sizes the series (dropping) resistor for a shunt Zener regulator, Rs = (Vin − Vz)/(Iz + Il), from the input voltage, the Zener voltage, the load current and the desired Zener (knee) current, and gives the power the resistor and the Zener must dissipate — the core design step so the diode stays in regulation at maximum load. The regulator endpoint analyses an existing regulator: from the input voltage, the Zener voltage, the series resistor and the load (as a current or a resistance) it computes the total current, the Zener current Iz = (Vin − Vz)/Rs − Il, the load current, the output voltage and whether the regulator is still regulating (Iz > 0) or has dropped out under heavy load. The power endpoint computes the Zener power dissipation P = Vz·Iz and the maximum safe current Iz_max = Pz_max/Vz from the diode's power rating. Voltages are in volts, currents in amperes, resistances in ohms and power in watts. Everything is computed locally and deterministically, so it is instant and private. Ideal for electronics, power-supply, hobbyist and embedded app developers, regulator-design and reference-voltage tools, and electronics education. Pure local computation — no key, no third-party service, instant. Live, nothing stored. 3 endpoints. This is the Zener shunt regulator; for BJT biasing use a transistor API and for an LED series resistor an LED-resistor API.

api.oanor.com/zener-api

Frequently asked questions

Quick answers about pricing, quotas, and integration.

How do I get an API key for Voltage Divider API?
Sign up for free at oanor.com, generate an API key from the developer dashboard, and call Voltage Divider API with the x-oanor-key header. No credit card needed for the free tier.
What's the rate limit for Voltage Divider API?
Free tier allows 1 request per second. Paid plans scale up to 50 requests per second on the Mega tier. Hard limits return HTTP 429 above the quota — no surprise overage charges.
How much does Voltage Divider API cost?
Voltage Divider API has a free tier with 100 calls / month. Paid plans start at €5.20 / month with higher quotas and faster rate limits.
Can I cancel my subscription anytime?
Yes. Plans are billed monthly and you can cancel anytime from your billing dashboard. No long-term contracts and no cancellation fee.
Is Voltage Divider API GDPR-compliant?
All requests to Voltage Divider API go through our EU-based gateway. Your upstream API key never leaves our server and no personal data is shared with the upstream provider beyond the request you send.

Pick an endpoint from the list on the left to see its details and try it.

Code snippets

Sign up to get an API key, then call any path under your slug.

curl https://api.oanor.com/voltagedivider-api/SOME_PATH \
  -H "x-oanor-key: oanor_test_..."
const res = await fetch("https://api.oanor.com/voltagedivider-api/SOME_PATH", {
  headers: { "x-oanor-key": "oanor_test_..." }
});
const data = await res.json();
$ch = curl_init("https://api.oanor.com/voltagedivider-api/SOME_PATH");
curl_setopt($ch, CURLOPT_RETURNTRANSFER, true);
curl_setopt($ch, CURLOPT_HTTPHEADER, ["x-oanor-key: oanor_test_..."]);
$response = curl_exec($ch);
import requests
r = requests.get(
    "https://api.oanor.com/voltagedivider-api/SOME_PATH",
    headers={"x-oanor-key": "oanor_test_..."},
)
print(r.json())

Ratings

Sign in to rate.

No reviews yet.

Discussion

Ask questions, share usage tips, get answers from the provider and other developers. Public — anyone can read.

Sign in to start a thread or reply.

Sign in

New thread

/ 4000

📌 Pinned 🔒 Locked

·

· ·

/ 4000

🔒 This thread is locked — no new replies.

  • No threads yet — start the discussion.

Support

Private 1:1 support with the provider — billing questions, integration issues, account problems. Only you and the provider team can see these threads.

Sign in to open a support ticket.

Sign in

Open new ticket

Describe what you need help with. The provider team gets an email and replies on the ticket page.

  • No tickets yet for this API.

Subscription active — calls can start immediately.

Send your first request —

Subscription active — copy a snippet and fire off your first call.